FR WIRE

MULTISTAND (90 MTRS)


ITEM CODE SIZE PARTICULARS CORE MRP
90001 24/0.2 0.75 SQ MM 1 870.00
90002 14/0.3 1.0 SQ MM 1 950.00
90003 22/0.3 1.5 SQ MM 1 1390.00
90004 28/0.3 2.0 SQ MM 1 1760.00
90005 36/0.3 2.5 SQ MM 1 2210.00
90006 56/0.3 4.0 SQ MM 1 3350.00
90007 84/0.3 6.0 SQ MM 1 4930.00
90008 140/0.3 10.0 SQ MM 1 8400.00
90009 126/0.4 16.0 SQ MM 1 14100.00
90010 196/0.4 25.0 SQ MM 1 22200.00
90011 276/0.4 35.0 SQMM 1 31100.00
90012 396/0.4 50.0 SQ MM 1 45100.00
90013 440/0.5 70.0 SQ MM 1 64500.00

MULTISTAND (180 MTRS)


ITEM CODE SIZE PARTICULARS CORE MRP
90021 24/0.2 0.75 SQ MM 1 1575.00
90022 14/0.3 1.0 SQ MM 1 1735.00
90023 22/0.3 1.5 SQ MM 1 2620.00
90024 28/0.3 2.0 SQ MM 1 3355.00
90025 36/0.3 2.5 SQ MM 1 4220.00
90026 56/0.3 4.0 SQ MM 1 6455.00

MULTISTAND (270 MTRS)

ITEM CODE SIZE PARTICULARS CORE MRP
90027 24/0.2 0.75 SQ MM 1 2360.00
90028 14/0.3 1.0 SQ MM 1 2600.00
90029 22/0.3 1.5 SQ MM 1 3920.00
90030 28/0.3 2.0 SQ MM 1 5030.00
90031 36/0.3 2.5 SQ MM 1 6330.00
90032 56/0.3 4.0 SQ MM 1 9700.00

MULTISTAND (45 MTRS)

ITEM CODE SIZE PARTICULARS CORE MRP
90014 24/0.2 0.75 SQ MM 1 428.00
90015 14/0.3 1.0 SQ MM 1 465.00
90016 22/0.3 1.5 SQ MM 1 685.00
90017 28/0.3 2.0 SQ MM 1 880.00
90018 36/0.3 2.5 SQ MM 1 1110.00
90019 56/0.3 4.0 SQ MM 1 1680.00
90020 84/0.3 6.0 SQ MM 1 2420.00

FR PROPERTIES

Test Test Method Specified Specification Values
Critical Oxygen Index IS:10810 Part 58 Oxygen Index Minimum 29%
Temperature Index IS:10810 Part 64 Minimum Temperture Index 250°C
Also meet requirements of Flammability Test as per IS 694:90

To add to the exisiting range of electrical wires, Kusum cables & wires pvt ltd introduces AIRSON”- Flame Retarndent (FR) PVC Insulated Indudtrial cables, which offer added safety.

Each wire is manufactured using 99.97% pure, electrolytic grade , bright annealed bare copper with more than 100% conductivity for conductor. This copper is manufactured at the company’s sate-of-the-art plant in Delhi. Highest putity and conductivity of copper ensures greater saving of electrical energy and thus helps to reduce electricity bills. The conductor is made of multiple strands of finely drawn copper wires thereby offring greater flexibility which makes these wires ideal for conduit wiring

The wires are insulated with FR (flame retrandent) PVC compound, specially formulated and manufactured in house. A special grade PVC resin manufactured by the group company, kusum cables & wires pvt ltd , is used to manufacture this compound. This PVC compound has FR properties of high oxygen and temperature index. These properties helpin restricting the spread of fire even at very high temperatures. This special compound also offers high insulation resistance and dielectric strength. Insulation is applied over the conductor by the process of dual extrusion using state – of- the – art extrusion lines. The outer skin determines the colour identification while the inner layer is pure insulation which provides extra protection . all wires are subjected to high voltage spark testing to make sure that there are no weak spots in insulation.

These ISI marked wires meet the requirements IS 694: 1990 with latest amendments with improved fire performance for category C-1. This means extra protection against electrical shocks, short circuits and fires.

By only from authorized KUSUM CALBELS & WIRES PVT LTD outlets to be assured of total quality. If doubt arises about the authenticity of the purchase, please write to the company at the address given below. Send a copy of the cash memo, coil number and a meter-length sample of cable to enable genuineness tests to be carried out in the laboratory . these wires are manufactured in our state-of-the art manufacturing plant at (delhi). The Kusum Cables & wires pvt ltd ÄIRSON”, company name and logo, size of wire, volatage grade FR type, ISI mark, licence no. are printed at regular intervals on the wire to help in easy indentification as shown below.

AIRSON - SINGLE CORE, UNSHEATHED WIRES IN VOLTAGE GRADE IN VOLTAGE GRADE 1100V.

Nominal area of copper Conductor Sq.mm Number / Nominal Diameter of strands mm Thickness of insulation (Nominal) mm Approximate Overall Diameter of wire mm
Current carrying capacity # 2 wires, single phase
In conduit/ Trunking Amps Unenclosed - cliped directly to a surface or on cable tray Amps
Resistance (Max.) Per km. @20 deegree C
0.75 24/.2** 0.6 2.3 6 7 26.00
1.0 14/.3* 0.7 2.7 11 12 18.10
1.5 22/.3* 0.7 3.1 13 16 12.10
2.5 36/.3* 0.8 3.7 18 22 7.41
4.0 56/.3** 0.8 4.3 24 29 4.95
6.0 84/.3** 0.8 4.8 31 37 3.30
Standard Colours : Black, Red, Blue, Yellow and Green (for earthing) Supplied in 45, 90, 180 & 270 mtr lenghts
# As per IS 3961(part V)-1968 Bis licence Nos. CM/L 2703549
* As per conductor class 2 of IS 8130:1984 ** As per conductor Class 8 of IS 8130:1984